ZW32-40.5 outdoor high voltage AC vacuum circuit breaker
Category: Product Center
key word:
Hotline:
ZW32-40.5 outdoor high voltage AC vacuum circuit breaker
Overview
ZW32-40.5 series outdoor high-voltage AC vacuum circuit breaker is a new type of miniaturized outdoor high-voltage AC switchgear independently developed by our company, with a rated voltage of 40.5kV, suitable for overhead lines, industrial and mining enterprises, power plants , substations, etc. This product can meet various protection and operation requirements of the power grid system, including closing and breaking short-circuit current, with excellent operating performance, high reliability, long service life and maintenance-free. With the FTU intelligent control terminal, it can communicate with the distribution network automation master station through GPRS or optical fiber to realize the distribution network automation function.
Product performance standards
| GB1984 GB/T 11022-2011 IEC 62271-100 GB311.1 DL/T 402 GB/T 3309 |
High Voltage AC Circuit Breaker Common technical requirements for high voltage switchgear and controlgear standards High Voltage AC Circuit Breaker Insulation coordination of high voltage power transmission and transformation equipment High-voltage vacuum circuit breaker ordering technical conditions Mechanical test of high voltage switchgear at normal temperature |
Product use conditions
◆Ambient temperature: -40℃ ~ +70℃
◆Altitude: ≤2000m
◆Relative humidity: 0~95%
◆Wind speed: ≤34m/s
◆Pollution level: ≤ Ⅳ level
◆Icing thickness: ≤10mm
◆Earthquake intensity: ≤ 8 degrees
Note: This product is not suitable for fire, explosion hazard, chemical corrosion and severe vibration and other places.
Product model description

technical parameter
The main technical parameters
| project |
Units |
Reference value |
|
|
Rated voltage |
kV |
40.5 |
|
|
Rated insulation level |
Lightning impulse withstand voltage |
kV |
185 |
|
1min power frequency withstand voltage |
kV |
95 |
|
|
Rated frequency |
Hz |
50 |
|
|
Rated current |
A |
630/1250/1600 |
|
|
Rated short-circuit breaking current |
kA |
20/25/31.5 |
|
|
Rated short-circuit making current (peak value) |
kA |
50/63/80 |
|
|
Rated short-time withstand current (4S) |
kA |
20/25/31.5 |
|
|
Nominal operating sequence |
|
O-0.3S-C0-180S-CO |
|
|
Rated short-circuit breaking times |
times |
30 |
|
|
Mechanical life |
times |
10000 |
|
Mechanical parameters
| project |
Units |
Reference value |
|
Distance |
mm |
18±1 |
|
Overtravel |
mm |
4±1 |
|
Average closing speed |
m/s |
0.6±0.2 |
|
Average opening speed |
m/s |
1.2±0.2 |
|
Close bounce |
ms |
≤3 |
|
Different periods |
ms |
≤2 |
|
Loop resistance |
μΩ |
≤60 |
Product Structure

Technical parameters of control box
| Function |
Metrics |
Number and details of function points |
|
Current sampling |
5A/1A |
4 (3-way phase current 1-way zero sequence current) |
|
Voltage sampling |
AC220V/AC100V |
4 (2 line voltage or 3 line phase voltage 1 line zero sequence voltage) |
|
remote input |
empty node |
7 (7-way opening, such as opening and closing position, energy storage position, etc.) |
|
Communication input |
AC165~265V |
1 (normal configuration 1-way can be configured with 2-way automatic switching if required) |
|
align switch |
Flick switch |
Opening and closing energy storage DC24V 300W |
|
Communication protocol |
IEC101 Balanced, Unbalanced IEC104 DNP3.0 ModBus |
|
Control box performance parameters
| feature |
Units |
Metrics |
|
AC current loop overload capacity |
|
2In, continuous work; 10In, 10s; 20In, 1s |
|
AC voltage loop overload capacity |
|
1.5Un continuous work |
|
Remote Signaling Resolution |
ms |
≤2ms |
|
Software anti-shake time |
ms |
0~6000ms can be set |
|
Device Power Consumption |
w |
≤15w |
|
Measurement accuracy |
% |
Voltage, current 0.5 %, active power, reactive power 1.0 % |
|
Backup power |
|
Maintain normal operation for more than 8 hours after AC power failure |
|
Controlling output node capacity |
|
DC24V/16A, AC250V/10A |
|
Insulation Properties |
MΩ |
≥5MΩ |
|
EMC |
|
IV |
|
Protection level |
IP |
IP54 |
|
Ambient temperature |
|
-40℃~+70℃, the maximum temperature change rate, 1.0℃/min |
|
Ambient humidity |
|
Relative humidity 10~100 %, maximum absolute humidity, 35g/㎥ |
Feature introduction
Telemetry function: It can detect AC analog quantities such as voltage and current, and DC analog quantities such as battery voltage and temperature.
Remote signaling function: It can detect status information such as switch status signal, switch energy storage signal, battery low voltage alarm, etc., and has dual-position remote signaling processing function to support remote signaling displacement priority transmission.
Remote control function: radio frequency wireless remote control opening and closing. Equipped with a local/remote selection switch, which can be connected to the master station to remotely control the opening and closing.
Fault detection function: configure single-phase grounding, three-stage phase-to-phase protection, overload, anti-inrush current protection and other protection functions, and record the protection current.
Communication function: with serial port and network communication interface, built-in 101, 104 and other power industry standard communication protocols, can upload data to the master station through optical fiber/Ethernet, GPRS/CDMA, etc.
Self-diagnosis and self-recovery function: with self-diagnosis function, when internal software and hardware abnormalities are found, they can be recorded and reported in time, and the software has the function of self-recovery after power-on.
Power management function: support dual-channel AC backup power supply, use battery as backup power supply, and use soft switching technology to cut in seamlessly. When the main power supply fails, the backup power supply can be automatically and seamlessly switched on; it has the function of battery activation management, which can be realized automatically and manually Charge and discharge the battery.